Skip to main content

Ring Pump – Comparison of Tube Inner Wall Wear

- between Ring Pumps and conventional peristaltic pumps from other manufacturers.

After continuously operating the Ring Pumps and a peristaltic pump from another manufacturer under the following conditions for 500 hours, the condition of tube inner wall wear was compared (weight of wear particles).

Test condition

Tube: Silicone 4 x 6 mm (ID x OD)
Operating time: 500 hours (@ room temperature)
Discharge rate: 50 ml/min
Pumps:
1. One roller Ring Pump
2. Two roller peristaltic pump from other manufacturer

Comparison of weight of wear particles

Ring Pump Comparison of weight of wear particles

Photo of tube inner wall wear particles

Ring Pump - Photo of tube inner wall wear particles