Ring Pump – Comparison of Tube Inner Wall Wear
- between Ring Pumps and conventional peristaltic pumps from other manufacturers.
After continuously operating the Ring Pumps and a peristaltic pump from another manufacturer under the following conditions for 500 hours, the condition of tube inner wall wear was compared (weight of wear particles).
Test condition
Tube: Silicone 4 x 6 mm (ID x OD)
Operating time: 500 hours (@ room temperature)
Discharge rate: 50 ml/min
Pumps:
1. One roller Ring Pump