Skip to main content

Pumping volume optimised valves (Zero-Pumping Volume)

When switching diaphragm-separated solenoid valves, the separation diaphragm creates a push-back effect, as the separation diaphragm sucks and releases volume through its movement. This pumping effect often has a negative influence on high-tech analytical instruments, such as high-precision dosing using a dispensing needle. By minimising this effect, a highly accurate dosage is possible.

Due to this optimisation, diaphragm-separated solenoid valves from the EXAKN or MTV series offer up to 100 times less pumping volume effect, than conventional diaphragm-separated valves.

Pumping volume EXAKN series

Port
ON - 1 (µl)
OFF - 1 (µl)
ON - 2 (µl)
OFF - 2 (µl)
ON - 3 (µl)
OFF - 3 (µl)
COM
+ 0,002
- 0,015
+ 0,002
- 0,015
+ 0,002
- 0,015
NC
+ 0,024
- 0,010
+ 0,024
- 0,010
+ 0,024
- 0,010
NO
+ 0,005
- 0,005
+ 0,005
- 0,005
+ 0,005
- 0,005